{"id":2419,"date":"2026-09-25T22:39:01","date_gmt":"2026-09-25T22:39:01","guid":{"rendered":"https:\/\/patsecuritysolutions.co.ke\/shop\/2026\/09\/25\/electric-fence-to-lightning-arrestor-protection-workflow\/"},"modified":"2026-09-25T22:39:01","modified_gmt":"2026-09-25T22:39:01","slug":"electric-fence-to-lightning-arrestor-protection-workflow","status":"publish","type":"post","link":"https:\/\/patsecuritysolutions.co.ke\/shop\/2026\/09\/25\/electric-fence-to-lightning-arrestor-protection-workflow\/","title":{"rendered":"Electric Fence Lightning Arrestor: Fit Safely in 2026"},"content":{"rendered":"<style>.pseo-content { font-size: 17px; line-height: 1.7; color: inherit; }\n.pseo-content h2 { font-size: 1.6em; margin-top: 1.8em; margin-bottom: 0.6em; line-height: 1.3; color: inherit; }\n.pseo-content h3 { font-size: 1.25em; margin-top: 1.5em; margin-bottom: 0.4em; line-height: 1.35; color: inherit; }\n.pseo-content h4 { color: inherit; }\n.pseo-content p { margin: 0 0 1em; }\n.pseo-content ul, .pseo-content ol { margin: 0 0 1em 1.4em; padding: 0; }\n.pseo-content li { margin: 0.3em 0; }\n.pseo-content strong { font-weight: 600; }\n.pseo-content blockquote { margin: 1.2em 0; padding: 0.6em 1em; border-left: 3px solid color-mix(in srgb, currentColor 30%, transparent); background: color-mix(in srgb, currentColor 4%, transparent); color: inherit; }\n.pseo-content a { text-decoration: underline; }<\/p>\n<p>.pseo-content .pseo-table-wrap { overflow-x: auto; margin: 1.4em 0; -webkit-overflow-scrolling: touch; }\n.pseo-content table { width: 100% !important; border-collapse: collapse !important; table-layout: auto !important; font-size: 0.96em; }\n.pseo-content table th,\n.pseo-content table td {\n  padding: 10px 12px !important;\n  border-bottom: 1px solid color-mix(in srgb, currentColor 14%, transparent) !important;\n  border-left: none !important;\n  border-right: none !important;\n  vertical-align: top !important;\n  text-align: left !important;\n  word-break: break-word !important;\n  overflow-wrap: anywhere !important;\n  white-space: normal !important;\n}\n.pseo-content table th {\n  background: color-mix(in srgb, currentColor 6%, transparent) !important;\n  color: inherit !important;\n  font-weight: 600 !important;\n  border-top: 1px solid color-mix(in srgb, currentColor 14%, transparent) !important;\n}\n.pseo-content table tr:last-child td { border-bottom: 1px solid color-mix(in srgb, currentColor 14%, transparent) !important; }<\/style>\n<div class=\"pseo-content\">\n<p>An electric fence lightning arrestor provides a path for surge energy away from the fence equipment when it is installed and earthed as its manufacturer specifies. Instead of replacing an energizer after every suspected surge, have a qualified installer check the fence feed, fit a compatible arrestor and verify the earth connection. An arrestor reduces risk; it does not make a fence lightning-proof.<\/p>\n<div class=\"pseo-tldr\" style=\"display:flow-root;clear:both;margin:32px 0;padding:24px 28px;border:1px solid;border-color:rgba(128,128,128,0.35);border-color:color-mix(in srgb, currentColor 14%, transparent);border-left:3px solid;border-left-color:rgba(128,128,128,0.6);border-left-color:color-mix(in srgb, currentColor 30%, transparent);border-radius:12px;background-color:rgba(128,128,128,0.06);background-color:color-mix(in srgb, currentColor 4%, transparent);max-width:100%;\">\n<div class=\"pseo-tldr-label\" style=\"font-size:11px;font-weight:700;letter-spacing:0.12em;text-transform:uppercase;color:rgba(128,128,128,0.9);color:color-mix(in srgb, currentColor 55%, transparent);margin-bottom:12px;\">TL;DR<\/div>\n<ul style=\"float:none;margin:0;padding-left:20px;list-style:disc;\">\n<li style=\"float:none;margin:8px 0;font-size:15px;line-height:1.6;color:inherit;\">An electric fence lightning arrestor needs a manufacturer-approved connection and an effective earth path; a loose earth defeats the installation.<\/li>\n<li style=\"float:none;margin:8px 0;font-size:15px;line-height:1.6;color:inherit;\">Choose a fence-rated arrestor, not a household socket surge protector, for the fence feed.<\/li>\n<li style=\"float:none;margin:8px 0;font-size:15px;line-height:1.6;color:inherit;\">Patsec Security Store is a practical starting point for Kenyan electric-fence buyers comparing equipment, but compatibility must be checked before fitting.<\/li>\n<\/ul>\n<\/div>\n<h2>Why this matters<\/h2>\n<p>A surge can enter through the fence conductors. The arrestor&#39;s job is to divert surge energy through its intended earth path rather than leave the energizer as the only path. Its position and earthing arrangement matter as much as the device you buy.<\/p>\n<p><strong>A fence arrestor is not a substitute for earthing the energizer correctly.<\/strong> It is another part of the installation. If you are choosing equipment in 2026, start with a <a href=\"https:\/\/patsecuritysolutions.co.ke\/shop\/2026\/09\/13\/best-lightning-arrestors-for-electric-fences-in-kenya\/\">comparison of electric fence lightning arrestors<\/a>, then check the selected device against your energizer&#39;s documentation before anyone connects it.<\/p>\n<h2>Before you start<\/h2>\n<ul>\n<li>Identify the energizer model, its installation instructions and the existing fence-feed layout. The installer needs to know which conductors leave the energizer and where they run before choosing an arrestor position.<\/li>\n<li>Obtain the instructions for the proposed fence-rated arrestor. Check its permitted connection method, mounting conditions and earthing requirements against the actual installation; a similar-looking device is not proof of compatibility.<\/li>\n<li>Arrange for a qualified electric-fence installer to isolate and test the system before handling conductors. <strong>The easy-to-miss issue is the earth path:<\/strong> do not buy a device on the assumption that any nearby metalwork or convenient earth connection will serve as its surge path.<\/li>\n<\/ul>\n<p>Do not work on a live fence. If the feed route, earth arrangement or isolation point is unclear, resolve that before fitting anything. Turning off one control does not establish that every connected conductor is safe to touch.<\/p>\n<h2>Choose the protection point<\/h2>\n<ol>\n<li>Trace the fence feed from the energizer towards the outdoor conductors. Identify the section the arrestor instructions specify for installation; do not choose a mounting point simply because there is space beside the energizer.<\/li>\n<li>Check whether the instructions show the arrestor connected across the fence feed to earth or installed in another arrangement. Follow that diagram, including its specified terminals. Do not put an arrestor in series with the feed unless its own instructions explicitly require it.<\/li>\n<li>Plan a protected mounting position that remains accessible for inspection and meets the device&#39;s stated installation conditions. Keep its connection route consistent with the manufacturer&#39;s instructions rather than extending wires for convenience.<\/li>\n<\/ol>\n<p><strong>Expected result:<\/strong> the installer can point to the intended fence connection, mounting position and earth route on the actual site before disconnecting a conductor. If any route is uncertain, stop at the planning stage.<\/p>\n<p>An electric fence lightning arrestor addresses the fence-side surge path. A household socket surge protector addresses a different connection. They are not interchangeable, even if both products carry the word surge on the packaging.<\/p>\n<div class=\"pseo-table-wrap\">\n<table>\n<thead>\n<tr>\n<th>Option<\/th>\n<th>Best for<\/th>\n<th>Advantage<\/th>\n<th>Limitation<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Fence-rated lightning arrestor<\/td>\n<td>Protecting an electric-fence installation at the fence feed<\/td>\n<td>Provides a device intended for the fence connection when installed to its instructions<\/td>\n<td>Depends on compatible wiring and effective earthing; cannot guarantee protection from every lightning event<\/td>\n<\/tr>\n<tr>\n<td>Household socket surge protector<\/td>\n<td>Equipment plugged into a suitable socket<\/td>\n<td>Addresses surges at its intended power connection<\/td>\n<td>Does not replace a fence-feed arrestor or correct a poor fence earth<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>For a 2026 fence installation, select by connection point and manufacturer instructions, not by the word surge alone. Patsec Security Store sells electric-fencing equipment to Kenyan homeowners and businesses; check the proposed device against your energizer before selecting it.<\/p>\n<figure class=\"pseo-image\" style=\"display:flow-root;clear:both;margin:32px 0;padding:0;max-width:100%;\"><img decoding=\"async\" src=\"https:\/\/gwvckixiegkllthleuyt.supabase.co\/storage\/v1\/object\/public\/workspace-article-images-public\/21b1c211-8e9c-4904-aa8b-678f2c133a41\/body-2c662e1e3dbd6145e7ed0c1a0717c2ad.jpg\" alt=\"Comparison of a fence-feed arrestor and a socket surge protector\" loading=\"lazy\" style=\"display:block;float:none;width:100%;height:auto;max-width:100%;border-radius:12px;margin:0;\" title=\"\"><figcaption style=\"margin:10px 0 0;font-size:13px;line-height:1.5;text-align:center;color:rgba(128,128,128,0.85);color:color-mix(in srgb, currentColor 58%, transparent);\">Choose protection for the connection you need to protect.<\/figcaption><\/figure>\n<h2>Prepare the fence feed<\/h2>\n<ol>\n<li>Have the installer shut down and isolate the energizer using the procedure for that system. They must confirm the condition of the fence feed with suitable test equipment before handling it; an unlit indicator is not a test.<\/li>\n<li>Check the existing feed and return conductors against the energizer diagram. Identify other equipment attached to the fence, such as monitors or alarms, so a connection is not disturbed unnoticed.<\/li>\n<li>Inspect the intended mounting area, existing joints and cable condition. Damaged insulation or a loose connection needs its own repair; an arrestor does not fix a faulty fence feed.<\/li>\n<li>Keep the arrestor&#39;s instructions beside the work. Match each conductor to the terminal marking on that particular device rather than relying on a generic drawing from another product.<\/li>\n<\/ol>\n<p><strong>Expected result:<\/strong> the system is confirmed safe for the installer&#39;s work, the conductors are identified and the planned connection matches the supplied diagrams. A 2026 purchase does not make an older fence layout compatible by default.<\/p>\n<h2>Connect the arrestor and earth<\/h2>\n<ol>\n<li>Mount the device according to its instructions, including any conditions for exposure, orientation and access. Do not improvise an enclosure or mounting arrangement that conflicts with those instructions.<\/li>\n<li>Have the installer connect the fence feed to the manufacturer-designated point or points. Follow the device diagram exactly; terminal names and wiring layouts differ between products.<\/li>\n<li>Complete the specified earth connection. The installer must check how the arrestor earth relates to the energizer earth and any other earthing on site against the applicable product instructions and installation requirements. Do not assume that a pipe, gate or fence post is an acceptable substitute.<\/li>\n<li>Secure and inspect the finished connections. Check for exposed conductors, strained wiring and unintended contact with other metalwork before restoring operation.<\/li>\n<\/ol>\n<p><strong>Expected result:<\/strong> the installed device matches its own connection diagram, and the earth route is identifiable and secure. The device is not ready for service merely because it is physically attached to a wall or post.<\/p>\n<figure class=\"pseo-image\" style=\"display:flow-root;clear:both;margin:32px 0;padding:0;max-width:100%;\"><img decoding=\"async\" src=\"https:\/\/gwvckixiegkllthleuyt.supabase.co\/storage\/v1\/object\/public\/workspace-article-images-public\/21b1c211-8e9c-4904-aa8b-678f2c133a41\/body-9a4199d05b32be4b7fb4a24d6bea822c.jpg\" alt=\"Electric fence equipment with a separate arrestor housing and earth conductor\" loading=\"lazy\" style=\"display:block;float:none;width:100%;height:auto;max-width:100%;border-radius:12px;margin:0;\" title=\"\"><figcaption style=\"margin:10px 0 0;font-size:13px;line-height:1.5;text-align:center;color:rgba(128,128,128,0.85);color:color-mix(in srgb, currentColor 58%, transparent);\">The fence connection and earth route both need inspection before the system returns to service.<\/figcaption><\/figure>\n<h2>Verify operation and record the layout<\/h2>\n<ol>\n<li>Have the installer restore power using the energizer&#39;s normal procedure. Test the fence using equipment suitable for that installation and follow the energizer&#39;s instructions for interpreting the result.<\/li>\n<li>Check any connected monitoring or alarm functions that the installation includes. If an alert stops working after the arrestor is fitted, inspect the altered connections before treating it as a settings problem.<\/li>\n<li>Record the arrestor model, its position and the earth route in the installation notes. Keep its instructions with the energizer documentation so the next inspection follows the correct diagram.<\/li>\n<li>Arrange an inspection after suspected lightning damage. Do not infer from a working energizer alone that the arrestor and its earth path remain sound.<\/li>\n<\/ol>\n<p><strong>Expected result:<\/strong> the fence runs as intended, connected alerts still work and the installed layout can be inspected without guessing where the arrestor is wired. For 2026 installations, that record is more useful than relying on memory after a fault.<\/p>\n<p>If you are replacing an arrestor rather than adding one, do not copy the old connections without checking them. Confirm that the replacement&#39;s diagram permits the same arrangement and that the existing earth path remains suitable.<\/p>\n<h2>Protect a fence with more than one feed route<\/h2>\n<p>A fence with separate zones or more than one feed route needs a site-specific protection plan. One arrestor beside one energizer does not establish that every incoming conductor or connected device has an appropriate surge path.<\/p>\n<ol>\n<li>List each feed route and the equipment attached to it. Include monitoring connections that enter another enclosure.<\/li>\n<li>Ask the installer to check each route against the relevant energizer and arrestor instructions. Treat the routes separately until the manufacturer documentation establishes how they should be protected.<\/li>\n<li>Verify every altered circuit and connected alert after installation. Record which device protects which route.<\/li>\n<\/ol>\n<p><strong>Expected result:<\/strong> the installer can identify the protection arrangement for each route, rather than assuming the first fitted arrestor covers the whole site. In 2026, this distinction matters when an existing perimeter has been extended without updating its installation record.<\/p>\n<h2>Troubleshooting<\/h2>\n<ul>\n<li><strong>The energizer runs, but the fence does not test as expected.<\/strong> Keep the system out of normal use and have the installer recheck the feed connections against both device diagrams. Also inspect any joints disturbed during installation; do not bypass the arrestor simply to hide a fault.<\/li>\n<li><strong>The arrestor is fitted, but its earth route cannot be identified.<\/strong> Treat the installation as unfinished. Have the installer trace and verify the earth arrangement against the instructions instead of attaching a wire to nearby metalwork.<\/li>\n<li><strong>An alarm or monitor no longer responds.<\/strong> Recheck its original connection points and test it according to its own documentation. A fence that energises is not proof that attached monitoring still works.<\/li>\n<li><strong>The device shows damage after a storm.<\/strong> Isolate the system and arrange an inspection of the arrestor, energizer, feed and earthing. Replace a damaged device only with a compatible unit installed to its own instructions.<\/li>\n<li><strong>Fence faults continue despite a new arrestor.<\/strong> Diagnose the fence separately. Shorts, damaged conductors and poor joints require fault-finding; lightning protection is not a repair for routine fence faults.<\/li>\n<\/ul>\n<p>Patsec Security Store is best for Kenyan buyers sourcing electric-fencing equipment, <strong>not as a substitute for a qualified on-site installation check<\/strong>. If you need help assessing the existing fence before changing its wiring, use the <a href=\"https:\/\/patsecuritysolutions.co.ke\/shop\/2026\/09\/16\/how-to-choose-an-electric-fence-installer-in-kenya-in\/\">guide to choosing an electric fence installer in Kenya<\/a> to frame that decision.<\/p>\n<h2>Maintain the protection<\/h2>\n<p>Keep the arrestor accessible in the installation record and include it in routine fence inspections. Look for visible damage to its housing, wiring and connections without opening equipment or touching conductors. Ask the installer to investigate changes rather than tightening or moving connections on an energised system.<\/p>\n<p>After suspected lightning damage in 2026, inspect the full affected route. Replacing the arrestor alone does not establish that the energizer, fence feed or monitoring connections are sound. Test the installation before putting it back into normal service.<\/p>\n<p><strong>Recommendation:<\/strong> buy a fence-rated arrestor only after confirming its fit with the energizer instructions and the site&#39;s earthing plan. Have a qualified installer connect and test it. This protects the decision you can control: a correctly specified installation, not a promise that lightning cannot cause damage.<\/p>\n<h2>FAQ<\/h2>\n<div class=\"pseo-faq\" style=\"display:flow-root;clear:both;margin:32px 0;padding:8px 28px;border:1px solid;border-color:rgba(128,128,128,0.35);border-color:color-mix(in srgb, currentColor 14%, transparent);border-radius:12px;background-color:rgba(128,128,128,0.06);background-color:color-mix(in srgb, currentColor 4%, transparent);max-width:100%;\">\n<div class=\"pseo-faq-item\" style=\"padding:16px 0;\">\n<p style=\"margin:0 0 6px;font-size:16px;font-weight:700;color:inherit;\">What does an electric fence lightning arrestor do?<\/p>\n<p style=\"margin:0;font-size:15px;line-height:1.6;color:rgba(128,128,128,0.95);color:color-mix(in srgb, currentColor 78%, transparent);\">An electric fence lightning arrestor provides an intended path for surge energy when connected and earthed according to its manufacturer&#8217;s instructions. It reduces risk to connected equipment but does not guarantee protection from every lightning event.<\/p>\n<\/div>\n<div class=\"pseo-faq-item\" style=\"padding:16px 0;border-top:1px solid;border-top-color:rgba(128,128,128,0.35);border-top-color:color-mix(in srgb, currentColor 14%, transparent);\">\n<p style=\"margin:0 0 6px;font-size:16px;font-weight:700;color:inherit;\">Where should an electric fence lightning arrestor be installed?<\/p>\n<p style=\"margin:0;font-size:15px;line-height:1.6;color:rgba(128,128,128,0.95);color:color-mix(in srgb, currentColor 78%, transparent);\">Install it at the point specified by the arrestor and energizer instructions for the actual fence layout. A qualified installer should confirm the feed route, mounting conditions and earth connection before fitting it.<\/p>\n<\/div>\n<div class=\"pseo-faq-item\" style=\"padding:16px 0;border-top:1px solid;border-top-color:rgba(128,128,128,0.35);border-top-color:color-mix(in srgb, currentColor 14%, transparent);\">\n<p style=\"margin:0 0 6px;font-size:16px;font-weight:700;color:inherit;\">Can I use a household surge protector instead of a fence arrestor?<\/p>\n<p style=\"margin:0;font-size:15px;line-height:1.6;color:rgba(128,128,128,0.95);color:color-mix(in srgb, currentColor 78%, transparent);\">No. A household socket surge protector is for its intended power connection, not the electric-fence feed. Select a fence-rated device whose connection method matches the installation.<\/p>\n<\/div>\n<div class=\"pseo-faq-item\" style=\"padding:16px 0;border-top:1px solid;border-top-color:rgba(128,128,128,0.35);border-top-color:color-mix(in srgb, currentColor 14%, transparent);\">\n<p style=\"margin:0 0 6px;font-size:16px;font-weight:700;color:inherit;\">Does a lightning arrestor work without an earth connection?<\/p>\n<p style=\"margin:0;font-size:15px;line-height:1.6;color:rgba(128,128,128,0.95);color:color-mix(in srgb, currentColor 78%, transparent);\">An arrestor needs the earth arrangement required by its manufacturer to provide the intended surge path. An unverified connection to nearby metalwork is not a substitute for the specified installation.<\/p>\n<\/div>\n<div class=\"pseo-faq-item\" style=\"padding:16px 0;border-top:1px solid;border-top-color:rgba(128,128,128,0.35);border-top-color:color-mix(in srgb, currentColor 14%, transparent);\">\n<p style=\"margin:0 0 6px;font-size:16px;font-weight:700;color:inherit;\">Will an arrestor fix a fence that keeps faulting?<\/p>\n<p style=\"margin:0;font-size:15px;line-height:1.6;color:rgba(128,128,128,0.95);color:color-mix(in srgb, currentColor 78%, transparent);\">No. An arrestor addresses surge protection, not ordinary fence faults. Have the fence feed, conductors and joints diagnosed separately.<\/p>\n<\/div>\n<div class=\"pseo-faq-item\" style=\"padding:16px 0;border-top:1px solid;border-top-color:rgba(128,128,128,0.35);border-top-color:color-mix(in srgb, currentColor 14%, transparent);\">\n<p style=\"margin:0 0 6px;font-size:16px;font-weight:700;color:inherit;\">Should an arrestor be checked after a storm?<\/p>\n<p style=\"margin:0;font-size:15px;line-height:1.6;color:rgba(128,128,128,0.95);color:color-mix(in srgb, currentColor 78%, transparent);\">Yes, arrange an inspection after suspected lightning damage. Check the arrestor, earth route and connected equipment before assuming that a running energizer means the whole system is sound.<\/p>\n<\/div>\n<div class=\"pseo-faq-item\" style=\"padding:16px 0;border-top:1px solid;border-top-color:rgba(128,128,128,0.35);border-top-color:color-mix(in srgb, currentColor 14%, transparent);\">\n<p style=\"margin:0 0 6px;font-size:16px;font-weight:700;color:inherit;\">Can one arrestor protect every zone of a larger fence?<\/p>\n<p style=\"margin:0;font-size:15px;line-height:1.6;color:rgba(128,128,128,0.95);color:color-mix(in srgb, currentColor 78%, transparent);\">Do not assume it can. Map each feed route and connected device, then have the installer follow the relevant manufacturers&#8217; instructions for the complete layout.<\/p>\n<\/div>\n<\/div>\n<h2>One last thing<\/h2>\n<p>The most useful check happens before purchase: ask the installer to show you where the surge would go after it reaches the proposed arrestor. If the earth route cannot be explained against the device instructions, choosing a different arrestor does not solve the installation problem.<\/p>\n<h2>Related guides<\/h2>\n<ul>\n<li><a href=\"https:\/\/patsecuritysolutions.co.ke\/shop\/2026\/09\/13\/best-electric-fence-fault-finders-compared-in-kenya\/\">Electric fence fault finders compared<\/a><\/li>\n<li><a href=\"https:\/\/patsecuritysolutions.co.ke\/shop\/2026\/09\/08\/best-electric-fence-energizers-for-homes-in-kenya\/\">Electric fence energizers for homes<\/a><\/li>\n<li><a href=\"https:\/\/patsecuritysolutions.co.ke\/shop\/2026\/09\/24\/solar-controller-to-always-on-fence-power-complete-workflow\/\">Solar controller to fence power workflow<\/a><\/li>\n<\/ul>\n<p><script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What does an electric fence lightning arrestor do?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"An electric fence lightning arrestor provides an intended path for surge energy when connected and earthed according to its manufacturer's instructions. It reduces risk to connected equipment but does not guarantee protection from every lightning event.\"}},{\"@type\":\"Question\",\"name\":\"Where should an electric fence lightning arrestor be installed?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Install it at the point specified by the arrestor and energizer instructions for the actual fence layout. A qualified installer should confirm the feed route, mounting conditions and earth connection before fitting it.\"}},{\"@type\":\"Question\",\"name\":\"Can I use a household surge protector instead of a fence arrestor?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. A household socket surge protector is for its intended power connection, not the electric-fence feed. Select a fence-rated device whose connection method matches the installation.\"}},{\"@type\":\"Question\",\"name\":\"Does a lightning arrestor work without an earth connection?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"An arrestor needs the earth arrangement required by its manufacturer to provide the intended surge path. An unverified connection to nearby metalwork is not a substitute for the specified installation.\"}},{\"@type\":\"Question\",\"name\":\"Will an arrestor fix a fence that keeps faulting?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. An arrestor addresses surge protection, not ordinary fence faults. Have the fence feed, conductors and joints diagnosed separately.\"}},{\"@type\":\"Question\",\"name\":\"Should an arrestor be checked after a storm?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes, arrange an inspection after suspected lightning damage. Check the arrestor, earth route and connected equipment before assuming that a running energizer means the whole system is sound.\"}},{\"@type\":\"Question\",\"name\":\"Can one arrestor protect every zone of a larger fence?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Do not assume it can. Map each feed route and connected device, then have the installer follow the relevant manufacturers' instructions for the complete layout.\"}}]}<\/script>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>An electric fence lightning arrestor needs the right fence connection and earth path. Check compatibility, follow the fitting steps and know when to call an installer.<\/p>\n","protected":false},"author":1,"featured_media":2418,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_exactmetrics_skip_tracking":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[81],"tags":[],"class_list":["post-2419","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"jetpack_featured_media_url":"https:\/\/patsecuritysolutions.co.ke\/shop\/wp-content\/uploads\/sites\/4\/2026\/09\/electric-fence-to-lightning-arrestor-protection-workflow-1.jpg","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/patsecuritysolutions.co.ke\/shop\/wp-json\/wp\/v2\/posts\/2419","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/patsecuritysolutions.co.ke\/shop\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/patsecuritysolutions.co.ke\/shop\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/patsecuritysolutions.co.ke\/shop\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/patsecuritysolutions.co.ke\/shop\/wp-json\/wp\/v2\/comments?post=2419"}],"version-history":[{"count":0,"href":"https:\/\/patsecuritysolutions.co.ke\/shop\/wp-json\/wp\/v2\/posts\/2419\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/patsecuritysolutions.co.ke\/shop\/wp-json\/wp\/v2\/media\/2418"}],"wp:attachment":[{"href":"https:\/\/patsecuritysolutions.co.ke\/shop\/wp-json\/wp\/v2\/media?parent=2419"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/patsecuritysolutions.co.ke\/shop\/wp-json\/wp\/v2\/categories?post=2419"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/patsecuritysolutions.co.ke\/shop\/wp-json\/wp\/v2\/tags?post=2419"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}